Hemel Hempstead 2 Data Center is located in suburb of London. Low risk of floods and terrorism compare to central London.
Car parking facilities are present on site.
Fence
3.6 m-high perimeter fence encapsulates all of the data center secure sections.
Customers need to pass through two security gates with anti-passback when customers enter Hemel Hempstead 2 Data Center’s premises by vehicle to carry in their equipment.
Security officers use Hemel Hempstead 2 Data Center’s access control and permit to work system to issue access cards to the authorized people for the appropriate areas.
RECEPTION
The security office is manned 24 hours a day.
MEETING ROOM
There are meeting rooms available.
Free Wi-Fi is also available.
CAFETERIA
Hemel Hempstead 2 Data Center has breakout area.
High security anti-tailgating portal doors are used for entrance into the high security data center area.
IRIS SCAN AUTHENTICATION DEVICE
Customers go through the gate by using IC card and Iris scan authentication.
Metal checker plating is applied to lower part of the data center wall to prevent damage during carry-in/out work.
Customers do not need to implement care protection each time.
GAS ROOM
Each standard server room has IG55 gas fire suppression system and Very Early Smoke Detection Apparatus that detect fire at an early stage.
Authorized IC card is required to enter the server room.
CCTV cameras are installed at all entrance/exit of server room.
1/3 RACK
Our server room is populated with either 52U or 16U 1/3rd size racks.
Server rooms in Hemel Hempstead 2 Data Center only have “Cold aisle area”.
Chimney racks make the air flow system possible.
Hot air from the rack returns to Air Handling Unit directly through chimney on top of the rack.
This cooling methodology enables high-power provision to rack. (20kW per rack)
Our server room is populated with either 52U or 16U 1/3rd size racks.
Server rooms in Hemel Hempstead 2 Data Center only have “Cold aisle area”.
Chimney racks make the air flow system possible.
Hot air from the rack returns to Air Handling Unit directly through chimney on top of the rack.
This cooling methodology enables high-power provision to rack. (20kW per rack)
CAGE
We can provide caged areas to customers’ specification including caging beneath the floor and above the false ceiling.
The cooling corridor houses N+1 Recirculating Air Handling Units.
The cooling corridor houses N+1 Recirculating Air Handling Units.
BATTERY
This is the battery room of UPS.
When in the case of power failure, batteries provide power to the server rooms until generators will start-up.
Power receiving room and UPS room are protected by one hour fire seal.
ROTARY UPS
Rotary UPS is also available for customers who has booked large space.